BD-1404B


Operation mode

transformer / indicator

Purpose

sensor

Power supply, V

110±5,5

Power supply frequency

50±1,5

Power consumption, W not more than

15

Maximum synchronization voltage, V

150±8

Current consumption, A not more than

0,46

Error following selsyns receivers, °

-       1 accuracy class not more than

-       2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

-       1 accuracy class not more than

-       2 accuracy class not more than


from 0 to ±0,25

more than ±0,25 to ±0,5

Operating temperature range, °С

from -50 to +50

Relative humidity upper value, % at 40°C

98

Weight, kg, not more than

1,2

General storage and operation warranty period, year

6,5

BD-1501


Operation mode

transformer / indicator

Purpose

sensor

Power supply, V

110±5,5

Power supply frequency

50±1,5/60±1,8

Power consumption, W not more than

28/27

Maximum synchronization voltage, V

55±2/57±2

Current consumption, A not more than

1,3/1,2

Error following selsyns receivers, °

-       1 accuracy class not more than

-       2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

-       1 accuracy class not more than

-       2 accuracy class not more than


from 0 to ±0,35

more than ±0,35 to ±0,5

Operating temperature range, °С

from -60 to +85

Relative humidity upper value, % atи 40°C

98

Weight, kg, not more than

4,15

General storage and operation warranty period, year

12

BD-1501B

Operation mode

indicator

Purpose

sensor

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

25

Maximum synchronization voltage, V

152±8

Current consumption, A not more than

1,35

Error following selsyns receivers, °

-       1 accuracy class not more than

-       2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

-       1 accuracy class not more than

-       2 accuracy class not more than

from 0 to ±0,35

more than ±0,35 to ±0,5

Operating temperature range, °С

from -50 to +50

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

4,15

General storage and operation warranty period, year

6,5

BS-1404

Operation mode

indicator

Purpose

receiver

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

16,5

Maximum synchronization voltage, V

51±3

Current consumption, A not more than

0,44

Error following selsyns receivers, °

-       1 accuracy class not more than

-       2 accuracy class not more than

from 0 to ±0,75

more than ±0,75 to ±1,5

Sensors selsyns zero points asymmetry, °

-       1 accuracy class not more than

-       2 accuracy class not more than


Operating temperature range, °С

from -60 to +85

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

1,45

General storage and operation warranty period, year

12

BS-1404B

Operation mode

indicator

Purpose

receiver

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

15

Maximum synchronization voltage, V

150±8

Current consumption, A not more than

0,46

Error following selsyns receivers, °

-       1 accuracy class not more than

-       2 accuracy class not more than

from 0 to ±0,75

more than ±0,75 to ±1,5

Sensors selsyns zero points asymmetry, °

-       1 accuracy class not more than

-       2 accuracy class not more than


Operating temperature range, °С

from -50 to +50

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

1,25

General storage and operation warranty period, year

6,5

BS-1404P

Operation mode

indicator

Purpose

receiver

Power supply, V

110±5,5

Power supply frequency, Hz

400±12/500±15

Power consumption, W not more than

23/19

Maximum synchronization voltage, V

100±4

Current consumption, A not more than

0,9/0,7

Error following selsyns receivers, °

-       1 accuracy class not more than

-       2 accuracy class not more than

from 0 to ±0,75

more than ±0,75 to ±1,5

Sensors selsyns zero points asymmetry, °

-       1 accuracy class not more than

-       2 accuracy class not more than


Operating temperature range, °С

from -60 to +85

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

1,26

General storage and operation warranty period, year

6,5

BS-1405

Operation mode

transformer

Purpose

receiver

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

2,5

Maximum synchronization voltage, V

34±2

Current consumption, A not more than

0,09

Error following selsyns receivers, °

-       1 accuracy class not more than

-       2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

-       1 accuracy class not more than

-       2 accuracy class not more than

from 0 to ±0,3

more than ±0,3 to ±0,5

Operating temperature range, °С

from -60 to +85

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

1,25

General storage and operation warranty period, year

12

BS-1405B

Operation mode

transformer

Purpose

receiver

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

2,5

Maximum synchronization voltage, V

78±3

Current consumption, A not more than

0,09

Error following selsyns receivers, °

-       1 accuracy class not more than

-       2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

-       1 accuracy class not more than

-       2 accuracy class not more than

from 0 to ±0,25

more than ±0,25 to ±0,5

Operating temperature range, °С

from -50 to +50

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

1,2

General storage and operation warranty period, year

6,5

BS-1501

Operation mode

indicator

Purpose

receiver

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5/60±1,8

Power consumption, W not more than

26/25

Maximum synchronization voltage, V

55±2/57±2

Current consumption, A not more than

1,3/1,2

Error following selsyns receivers, °

-       1 accuracy class not more than

-       2 accuracy class not more than

from 0 to ±0,75

more than ±0,75 to ±1,5

Sensors selsyns zero points asymmetry, °

-       1 accuracy class not more than

-       2 accuracy class not more than


Operating temperature range, °С

from -60 to +85

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

4,4

General storage and operation warranty period, year

6,5

BS-1501B

Operation mode

indicator

Purpose

receiver

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

25

Maximum synchronization voltage, V

152±8

Current consumption, A not more than

1,35

Error following selsyns receivers, °

-       1 accuracy class not more than

-       2 accuracy class not more than

from 0 to ±0,75

more than ±0,75 to ±1,5

Sensors selsyns zero points asymmetry, °

-       1 accuracy class not more than

-       2 accuracy class not more than


Operating temperature range, °С

from -50 to +50

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

4,4

General storage and operation warranty period, year

6,5