About product

Contact Selsyns SS-150TV, SS - 405TV, DI-150TV, DI-423TV, DN-500TV, DID-505TV, ND-1521TV are intended to be used in a humid tropical climate, have got the same technical characteristics as non-tropical contact selsyns, but the tropical contact selsyns operating temperatures range varies from 3 to 45°C, the relative humidity upper value is 95% at temperatures up to 35°C.

DID-1101

Operation mode

differential

Purpose

sensor

Power supply, V

50±2

Power supply frequency, Hz

50±1,5

Power consumption, W not more than


Maximum synchronization voltage, V

53±2

Current consumption, A not more than

0,15

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,25

more than ±0,25 to±0,5

Operating temperature range, °C

from -50 to +50

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

0,85

General storage and operation warranty period, year

6,5

DID-1101P

Operation mode

differential

Purpose

sensor

Power supply, V

100±5

Power supply frequency, Hz

400±12/500±15

Power consumption, W not more than


Maximum synchronization voltage, V

95±4

Current consumption, A not more than

0,13/0,11

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,25

more than ±0,25 to±0,5

Operating temperature range, °C

from -60 to +85

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

0,85

General storage and operation warranty period, year

6,5

DN-500

Operation mode

indicator

Purpose

sensor

Power supply, V

         +6

127

         -13

Power supply frequency, Hz

50

Power consumption, W not more than

12

Maximum synchronization voltage, V

58±2

Current consumption, A not more than

0,6

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,25

more than ±0,25 to±0,5

Operating temperature range, °C

from -43 to +58

Upper relative humidity value, % at 20°C

98

Weight, kg, not more than

3

General storage and operation warranty period, year

3,5

ND-1204

Operation mode

indicator

Purpose

sensor

Power supply, V

110±5,5

Power supply frequency, Hz

400±12/500±15

Power consumption, W not more than

6,5/5

Maximum synchronization voltage, V

100±4

Current consumption, A not more than

0,35/0,28

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,25

more than ±0,25 to±0,5

Operating temperature range, °C

from -60 to +85

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

0,39

General storage and operation warranty period, year

6,5

ND-1404

Operation mode

indicator

Purpose

sensor

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

11

Maximum synchronization voltage, V

49±2

Current consumption, A not more than

0,33

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,25

more than ±0,25 to±0,5

Operating temperature range, °C

from -50 to +50

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

0,85

General storage and operation warranty period, year

6,5

ND-1404A

Operation mode

indicator

Purpose

sensor

Power supply, V

55±2,75

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

8

Maximum synchronization voltage, V

46±2

Current consumption, A not more than

0,55

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,25

more than ±0,25 to±0,5

Operating temperature range, °C

from -50 to +85

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

0,85

General storage and operation warranty period, year

6,5

ND-1501

Operation mode

indicator

Purpose

sensor

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

13

Maximum synchronization voltage, V

57±2

Current consumption, A not more than

0,7

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,25

more than ±0,25 to±0,5

Operating temperature range, °C

from -60 to +85

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

3

General storage and operation warranty period, year

6,5

ND-1501B

Operation mode

indicator

Purpose

sensor

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

13

Maximum synchronization voltage, V

150±6

Current consumption, A not more than

0,7

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,35

more than ±0,35 to±0,5

Operating temperature range, °C

from -50 to +50

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

3

General storage and operation warranty period, year

6,5

ND-1511

Operation mode

indicator

Purpose

sensor

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

15

Maximum synchronization voltage, V

58±2

Current consumption, A not more than

1

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,25

more than ±0,25 to±0,5

Operating temperature range, °C

from -60 to +85

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

3,7

General storage and operation warranty period, year

6,5

НС-1404

Operation mode

indicator

Purpose

sensor

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

11

Maximum synchronization voltage, V

49±2

Current consumption, A not more than

0,33

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,75

more than ±0,75 to±1,5

Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than


Operating temperature range, °C

from -50 to +50

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

0,85

General storage and operation warranty period, year

6,5

NS-1501

Operation mode

indicator

Purpose

sensor

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

15

Maximum synchronization voltage, V

55±2

Current consumption, A not more than

0,75

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,75

more than ±0,75 to±1,5

Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than


Operating temperature range, °C

from -50 to +50

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

3

General storage and operation warranty period, year

6,5

NAD-1101

Operation mode

differential indicator

Purpose

sensor

Power supply, V

49±2

Power supply frequency, Hz

50±1,5

Power consumption, W not more than


Maximum synchronization voltage, V


Current consumption, A not more than


Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,75

more than ±0,75 to±1,5

Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than


Operating temperature range, °C

from -50 to +50

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

0,85

General storage and operation warranty period, year

6,5

DI-150

Operation mode

indicator

Purpose

sensor

Power supply, V

110±5,5

Power supply frequency, Hz

500±15

Power consumption, W not more than

4,4

Maximum synchronization voltage, V

48±2

Current consumption, A not more than

0,33

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,25

more than ±0,25 to±0,5

Operating temperature range, °C

from -40 to +50

Upper relative humidity value, % at 40°C

98

Weight, kg, not more than

0,28

General storage and operation warranty period, year

3,5

SS-150

Operation mode

indicator

Purpose

sensor

Power supply, V

110±5,5

Power supply frequency, Hz

500±15

Power consumption, W not more than

2,8

Maximum synchronization voltage, V

48±2

Current consumption, A not more than

0,19

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than

не более ±2,5

Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than


Operating temperature range, °C

from -40 to +50

Upper relative humidity value, % at 20°C

98

Weight, kg, not more than

0,19

General storage and operation warranty period, year

3,5

SS-405

Operation mode

transformer

Purpose

sensor receiver

Power supply, V

110±5,5

Power supply frequency, Hz

50±1,5

Power consumption, W not more than

7,5

Maximum synchronization voltage, V

51±2

Current consumption, A not more than

0,13

Error following selsyns receivers, °

    1 accuracy class not more than

    2 accuracy class not more than


Sensors selsyns zero points asymmetry, °

    1 accuracy class not more than

    2 accuracy class not more than

from 0 to ±0,25

more than ±0,25 to±0,5

Operating temperature range, °C

from -40 to +50

Upper relative humidity value, % at 20°C

98

Weight, kg, not more than

0,8

General storage and operation warranty period, year

3,5